What is the most accurate wearable for calories burned?
Fitbit ranks first for calorie estimates, followed by Samsung, Apple, Huawei and Garmin. It has the strongest overall comparative evidence among the brands tested, but that does not mean its calorie estimates are consistently accurate. Energy expenditure remains one of the weakest metrics on consumer wearables.
Calories burned accuracy by brand
The ranking is driven primarily by same-protocol comparisons against indirect calorimetry. Resistance, endurance, cycling and treadmill studies are considered separately because calorie algorithms behave very differently across activities.
Rank | Brand | Verdict |
|---|---|---|
1 | Strongest overall comparative evidence, but still inconsistent | |
2 | Strongest in steady running; poor for resistance exercise | |
3 | Reasonably consistent in some workouts, but large errors remain | |
4 | Excellent direct walking/running result, supported by additional field evidence | |
5 | Broad evidence, but modern head-to-head calorie results are often weak | |
NR | Promising Pixel Watch 3 result, but only one direct validation | |
NR | Useful single-device evidence, not enough comparative linkage | |
NR | More evidence now exists, but it is too fragmented for a stable brand rank | |
NR | Metabolic-chamber evidence exists, but error was high and replication is thin | |
NR | Direct calorimetry evidence exists, but it is one older intensity-dependent study | |
NR | Metabolic-chamber evidence exists, but not enough connected comparison evidence | |
NR | Strong result in one metabolic-chamber study, but too little replication for a brand rank |
How the ranking was decided
Calories are a derived estimate rather than a directly measured signal. The large systematic review found that no wearable brand was consistently accurate for energy expenditure, with fewer than 13% of brand comparisons falling within plus or minus 3% error. That is why this leaderboard should be read as a relative ranking among imperfect estimates.
Fitbit takes first because the strongest modern comparative network favours it overall. In the 70-person resistance-exercise comparison, Fitbit Charge 5 had 41.73% MAPE versus 84.48% for Samsung, 112.19% for Apple and 114.89% for Garmin. In the 62-person endurance and resistance study, Fitbit was almost on the group mean during resistance exercise, although it ran about 21% high during endurance work. Those are still large errors, but Fitbit wins more of the directly comparable conditions than the other brands.
There is an important Fitbit caveat. In the 2026 four-watch cycling study, its cleaned mean bias was only 3.14 kcal, but seven Fitbit readings exceeded 450% of the calorimetry value. When those failures were included, mean bias jumped to 128.6 kcal. That prevents first place from being described as reliable; it is simply the strongest overall position once all of the head-to-head evidence is considered.
Samsung ranks second. The 2025 maximal treadmill comparison was the one recent test where Samsung Galaxy Watch 7 actually met the authors' accuracy threshold, at 9.42% MAPE. Samsung also had the smallest group-mean endurance error in the four-watch endurance study. The problem is resistance exercise, where Galaxy Watch 5 error rose to 84.48% MAPE in the 70-person study. Separate Galaxy Watch 6 and 7 running validation is more encouraging, with roughly 10-13% MAPE.
Apple is third. It produced lower and more stable cycling error than Samsung and Garmin in the 2026 cycling comparison and had the strongest correlation with calorimetry during endurance exercise in the 62-person study. But its resistance-exercise estimates were extremely poor in both recent four-brand comparisons, and Apple Watch Ultra 2 recorded 25.95% MAPE in the maximal treadmill abstract. The Apple Watch living systematic review reaches the same broad conclusion: energy-expenditure error is inconsistent and often large.
Huawei moves into fourth on the strength of a direct same-participant comparison against Apple and Garmin. In the COSMED K5 walking and running study, Huawei Watch GT 2e recorded 9.9% MAPE while walking and 11.9% while running, compared with 19.8%/24.4% for Apple and 32.0%/21.8% for Garmin. That result is reinforced by the 24-hour metabolic-chamber study, where Huawei B2 was relatively close to the criterion, although a newer free-living ActiGraph study found much larger activity-energy error. The mixed replication is why Huawei does not leap above brands with broader evidence.
Garmin is fifth because its modern head-to-head results are consistently weaker. It had the largest group-mean overestimate during endurance exercise and resistance exercise in the 62-person comparison, 114.89% MAPE in the resistance study, and substantial overestimation in the cycling study. Its 14.65% treadmill MAPE in the conference abstract is better, but that lower-weight evidence is not enough to overturn the stronger within-subject comparisons.
Google, Oura, Polar, Amazfit, Suunto, Withings and Xiaomi remain unranked because the evidence is either too isolated, too old or insufficiently connected to the main comparison network. Pixel Watch 3 recorded 15.02% MAPE in a single-brand maximal treadmill validation. Oura Ring Gen 2 showed about 21% laboratory error in older validation work. Polar Vantage M3 recorded 21.10% MAPE in the treadmill abstract, but each device in that abstract was tested on a different participant group. Those studies are useful context, not enough to create defensible positions against the ranked network. The metabolic-chamber study adds Amazfit, Withings and Xiaomi evidence, while the five-stage running study adds Suunto and further Polar/Garmin evidence, but neither is enough on its own to justify additional numbered positions.
Supporting studies
FitbitFitbit Charge 5, Fitbit Sense 2, Fitbit device, Fitbit Charge 6, Fitbit Alta HR +1 more7 studies
Fitbit ranks first because it performs best across the strongest recent multi-brand resistance and mixed-exercise comparisons. That does not make its calorie number reliable: one cycling study produced several implausible Fitbit readings and the clean-looking average depended on removing them.
- Resistance exercise September 23, 2026Criterion Validity of Smartwatches for Measuring Heart Rate and Energy Expenditure During Resistance Exercise
Fitbit Charge 5 had the lowest error of the four devices in this resistance-exercise study, with 7.28 kcal mean bias and 41.73% MAPE, but agreement was still very poor (ICC 0.033) with wide limits.
- Exercise / lab July 29, 2026Body fat, skin tone, and the accuracy of smartwatch caloric expenditure estimates
After device-specific filtering, Fitbit Sense 2 had a mean bias of 3.14 kcal. However, seven implausible readings exceeded 450% of the calorimetry value; including them increased mean bias to 128.6 kcal. The study therefore found low average error only after excluding substantial device failures.
- Resistance exercise April 19, 2026Comparative Validity of Smartwatch-Derived Heart Rate and Energy Expenditure During Endurance and Resistance Exercise
Across the same 62 men, Fitbit averaged 246.19 kcal versus 203.75 kcal during endurance exercise, about 21% high. During resistance exercise it averaged 145.95 kcal versus 140.79 kcal, about 4% high, although agreement remained poor.
- Exercise / lab 2025Evaluating the Accuracy of Sex-Dependent Algorithms in Commercial Wrist-Worn Wearables for Exercise Energy Expenditure
Fitbit Charge 6 recorded 13.97% MAPE and Lin's concordance correlation of 0.94 in the sex-aligned condition.
- Review April 13, 2022Accuracy and Precision of Energy Expenditure, Heart Rate, and Steps Measured by Combined-Sensing Fitbits Against Reference Measures: Systematic Review and Meta-analysis
Pooled energy expenditure was underestimated by about 2.77 kcal per minute.
- Free living February 1, 2022Commercial Devices Provide Estimates of Energy Balance With Varying Degrees of Validity in Free-Living Adults
Fitbit Alta HR showed group-level agreement but individual energy-expenditure error remained meaningful; reported MAPE was roughly 9.3-12.5% across periods.
- Free living January 7, 2021Validity of Wrist-Wearable Activity Devices for Estimating Physical Activity in Adolescents: Comparative Study
Fitbit Flex overestimated 24-hour total energy expenditure by 287.0 kcal (about 14.1% of the criterion mean); TEE correlation was r=0.92.
SamsungSamsung Galaxy Watch 5, Samsung Galaxy Watch, Samsung Galaxy Watch 6, Samsung Galaxy Watch 75 studies
Samsung is second. Galaxy Watch is strongest in the maximal treadmill comparison and performs well during endurance exercise. Its weakness is resistance training, where error becomes very large.
- Resistance exercise September 23, 2026Criterion Validity of Smartwatches for Measuring Heart Rate and Energy Expenditure During Resistance Exercise
Galaxy Watch 5 overestimated workout energy expenditure by 112.00 kcal on average; MAPE was 84.48% and ICC was 0.029.
- Exercise / lab July 29, 2026Body fat, skin tone, and the accuracy of smartwatch caloric expenditure estimates
Galaxy Watch 5 overestimated physical-activity energy expenditure by 56.76 kcal on average.
- Resistance exercise April 19, 2026Comparative Validity of Smartwatch-Derived Heart Rate and Energy Expenditure During Endurance and Resistance Exercise
Across the same 62 men, Galaxy Watch averaged 221.50 kcal versus 203.75 kcal during endurance exercise, about 9% high. During resistance exercise it averaged 258.10 kcal versus 140.79 kcal, about 83% high.
- Exercise / lab March 18, 2026Validity of Galaxy Watch for Estimating Energy Expenditure During Intermittent Running: Cross-Sectional Study
Mean energy expenditure was 219.53 kcal versus 218.63 kcal from K5; overall Galaxy Watch MAPE was in the 10.10-12.55% range.
- Exercise / lab 2025Evaluating the Accuracy of Sex-Dependent Algorithms in Commercial Wrist-Worn Wearables for Exercise Energy Expenditure
Samsung Galaxy Watch 7 recorded 9.42% MAPE and Lin's concordance correlation of 0.96 in the sex-aligned condition.
AppleApple Watch Series 8, Apple Watch, Apple Watch Ultra 2, Apple Watch Series 9, Apple Watch Series 68 studies
Apple takes third. It is often more stable than Garmin and Samsung in cycling and has a deep validation literature, but direct modern studies show substantial errors during both endurance and especially resistance exercise.
- Resistance exercise September 23, 2026Criterion Validity of Smartwatches for Measuring Heart Rate and Energy Expenditure During Resistance Exercise
Apple Watch Series 8 overestimated workout energy expenditure by 156.24 kcal on average; MAPE was 112.19% and ICC was 0.022.
- Exercise / lab July 29, 2026Body fat, skin tone, and the accuracy of smartwatch caloric expenditure estimates
Apple Watch Series 8 overestimated physical-activity energy expenditure by 21.60 kcal on average.
- Resistance exercise April 19, 2026Comparative Validity of Smartwatch-Derived Heart Rate and Energy Expenditure During Endurance and Resistance Exercise
Across the same 62 men, Apple averaged 232.87 kcal versus 203.75 kcal from indirect calorimetry during endurance exercise, about 14% high. During resistance exercise it averaged 299.10 kcal versus 140.79 kcal, about 112% high.
- Review January 10, 2026The accuracy of Apple Watch measurements: a living systematic review and meta-analysis
Energy-expenditure error was inconsistent and frequently large across the literature.
- Exercise / lab 2025Evaluating the Accuracy of Sex-Dependent Algorithms in Commercial Wrist-Worn Wearables for Exercise Energy Expenditure
Apple Watch Ultra 2 recorded 25.95% MAPE and Lin's concordance correlation of 0.82 in the sex-aligned condition.
- Mixed December 17, 2024Accuracy of the Apple Watch Series 9 for Measures of Energy Expenditure and Heart Rate at Rest and During Exercise: Impact of Skin Pigmentation
Energy-expenditure estimates were inconsistent across exercise intensity and skin-pigmentation groups.
- Mixed 2024Using Apple Watch to Measure Heart Rate, Calorimetry, and Activity
Apple's white paper describes calorimetry validation for calorie estimation; results are manufacturer-reported and should be treated separately from independent evidence.
- Mixed September 26, 2022Validity of three smartwatches in estimating energy expenditure during outdoor walking and running
Energy-expenditure MAPE was 19.8% during walking and 24.4% during running.
HuaweiHuawei Watch GT2, Huawei Watch GT 2e, Huawei B23 studies
Huawei moves into fourth because it now connects directly to Apple and Garmin in a same-participant indirect-calorimetry study. Watch GT 2e recorded 9.9% MAPE while walking and 11.9% while running, substantially lower than both comparators in that protocol. Older metabolic-chamber and newer free-living evidence add breadth, although not all of it is equally strong.
- Free living December 20, 2024Accuracy of the Huawei GT2 Smartwatch for Measuring Physical Activity and Sleep Among Adults During Daily Life: Instrument Validation Study
Total daily activity energy expenditure agreement was ICC 0.75 with MAPE 33.79%; the Watch GT2 underestimated activity energy expenditure by about 50 kcal on average.
- Mixed September 26, 2022Validity of three smartwatches in estimating energy expenditure during outdoor walking and running
Energy-expenditure MAPE was 9.9% during walking and 11.9% during running.
- Free living January 7, 2021Validity of Wrist-Wearable Activity Devices for Estimating Physical Activity in Adolescents: Comparative Study
Huawei B2 underestimated 24-hour total energy expenditure by 115.9 kcal (about 5.7% of the criterion mean); TEE correlation was r=0.87 and the group estimate was close to the equivalence zone.
GarminGarmin Vivosmart 5, Garmin Forerunner 955, Garmin device, Garmin Vivoactive 4, Garmin Forerunner 265S +3 more8 studies
Garmin moves to fifth. It has broad evidence and one near-unbiased 24-hour metabolic-chamber result, but its modern same-protocol exercise comparisons include large errors, including 32.0% walking MAPE and 21.8% running MAPE against COSMED K5.
- Resistance exercise September 23, 2026Criterion Validity of Smartwatches for Measuring Heart Rate and Energy Expenditure During Resistance Exercise
Garmin Vivosmart 5 overestimated workout energy expenditure by 159.97 kcal on average; MAPE was 114.89% and ICC was 0.021.
- Exercise / lab July 29, 2026Body fat, skin tone, and the accuracy of smartwatch caloric expenditure estimates
Garmin Forerunner 955 overestimated physical-activity energy expenditure by 68.61 kcal on average.
- Resistance exercise April 19, 2026Comparative Validity of Smartwatch-Derived Heart Rate and Energy Expenditure During Endurance and Resistance Exercise
Across the same 62 men, Garmin averaged 265.87 kcal versus 203.75 kcal during endurance exercise, about 31% high. During resistance exercise it averaged 304.71 kcal versus 140.79 kcal, about 116% high.
- Exercise / lab January 27, 2026Accuracy of the Garmin Vivoactive 4 for Estimating Heart Rate, Energy Expenditure, and Step Count During Treadmill Exercise
Energy-expenditure MAPE was about 19.1%.
- Exercise / lab 2025Evaluating the Accuracy of Sex-Dependent Algorithms in Commercial Wrist-Worn Wearables for Exercise Energy Expenditure
Garmin Forerunner 265S recorded 14.65% MAPE and Lin's concordance correlation of 0.89 in the sex-aligned condition.
- Mixed September 26, 2022Validity of three smartwatches in estimating energy expenditure during outdoor walking and running
Energy-expenditure MAPE was 32.0% during walking and 21.8% during running.
- Free living January 7, 2021Validity of Wrist-Wearable Activity Devices for Estimating Physical Activity in Adolescents: Comparative Study
Garmin Vivofit differed from the metabolic-chamber criterion by only +1.9 kcal on average; TEE correlation was r=0.85 and the group estimate fell within the prespecified equivalence zone.
- Exercise / lab December 20, 2017Validity of sports watches when estimating energy expenditure during running
Energy-expenditure MAPE across the five running stages was 26.28%, 17.59%, 11.54%, 37.94%, 49.30%. Error was strongly intensity-dependent; all watches underestimated energy expenditure at the two highest intensities.
GoogleGoogle Pixel Watch 31 study
Pixel Watch 3 recorded 15.02% MAPE against indirect calorimetry in a maximal treadmill test. That is useful modern evidence, but it is a single-brand validation and cannot establish a relative position against the main connected network.
- Mixed September 15, 2026The Accuracy of VO2 max, Heart Rate and Energy Expenditure Measurements From Google Pixel Watch 3
Energy-expenditure error was larger than heart-rate error, with MAPE around 15%.
OuraOura Ring Gen 21 study
Oura Ring Gen 2 has laboratory and free-living energy-expenditure validation, including about 21% laboratory MAPE. The evidence is older and does not directly connect Oura to the modern multi-brand comparison network.
- Mixed September 1, 2023Correction: Validation of Oura Ring Energy Expenditure and Steps in Laboratory and Free-Living
Laboratory energy-expenditure MAPE was about 21.1%; Oura increasingly underestimated energy expenditure as exercise intensity rose.
PolarPolar Vantage M3, Polar Loop, Polar V8003 studies
Polar now has additional same-participant running evidence, including Polar V800 results across five intensities, but performance changes sharply with workload and the evidence remains too fragmented for a stable brand-wide rank.
- Exercise / lab 2025Evaluating the Accuracy of Sex-Dependent Algorithms in Commercial Wrist-Worn Wearables for Exercise Energy Expenditure
Polar Vantage M3 recorded 21.10% MAPE and Lin's concordance correlation of 0.85 in the sex-aligned condition.
- Free living January 7, 2021Validity of Wrist-Wearable Activity Devices for Estimating Physical Activity in Adolescents: Comparative Study
Polar Loop overestimated 24-hour total energy expenditure by 143.2 kcal (about 7.0% of the criterion mean); TEE correlation was r=0.96.
- Exercise / lab December 20, 2017Validity of sports watches when estimating energy expenditure during running
Energy-expenditure MAPE across the five running stages was 22.76%, 11.43%, 10.09%, 29.98%, 39.52%. Error was strongly intensity-dependent; all watches underestimated energy expenditure at the two highest intensities.
AmazfitAmazfit1 study
Amazfit now has metabolic-chamber energy-expenditure evidence, but its 26.4% MAPE was the highest of the 11 devices in that adolescent study. One study is not enough for a numerical brand position.
- Free living January 7, 2021Validity of Wrist-Wearable Activity Devices for Estimating Physical Activity in Adolescents: Comparative Study
Amazfit underestimated 24-hour total energy expenditure by 542.0 kcal (26.6% mean bias); TEE correlation was r=0.78 and MAPE was 26.4%, the largest MAPE among the tested devices.
SuuntoSuunto Ambit21 study
Suunto Ambit2 was tested directly against indirect calorimetry across five running intensities. Error ranged from roughly 21% to 42% and changed direction with intensity, so the result strengthens coverage without supporting a numbered rank.
- Exercise / lab December 20, 2017Validity of sports watches when estimating energy expenditure during running
Energy-expenditure MAPE across the five running stages was 41.93%, 36.30%, 21.32%, 23.05%, 31.85%. Error was strongly intensity-dependent; all watches underestimated energy expenditure at the two highest intensities.
WithingsWithings Pulse O21 study
Withings Pulse O2 underestimated 24-hour total energy expenditure by about 153 kcal in the metabolic-chamber study. The evidence is useful but too isolated for a relative brand rank.
- Free living January 7, 2021Validity of Wrist-Wearable Activity Devices for Estimating Physical Activity in Adolescents: Comparative Study
Withings Pulse O2 underestimated 24-hour total energy expenditure by 152.6 kcal (about 7.5% of the criterion mean); TEE correlation was r=0.86.
XiaomiXiaomi Mi Band 21 study
Mi Band 2 produced only 5.7% MAPE and fell within the equivalence zone in the metabolic-chamber study. That is a strong individual result, but the calorie evidence is too sparse and old to rank Xiaomi as a brand.
- Free living January 7, 2021Validity of Wrist-Wearable Activity Devices for Estimating Physical Activity in Adolescents: Comparative Study
Xiaomi Mi Band 2 underestimated 24-hour total energy expenditure by 59.5 kcal on average; TEE correlation was r=0.91, MAPE was 5.7%, and the estimate fell within the equivalence zone.